Created on 09/04/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 1 of 2
MODEL
RSBC
Pilot operated, balanced piston sequence valve
CAPACITY: 30 L/min. / CAVITY: T-163A
Pilot-operated, balanced piston sequence valves will supply a secondary circuit with flow once the pressure at the
inlet (port 1) has exceeded the valve setting. The pressure setting of a sequence valve controls the pressure at port
1 relative to the pressure at the drain (port 3). These valves are insensitive to back pressure at port 2 (sequence),
up to the valve setting. They may be used to regulate pressure in place of 2-port relief valves if there is pressure in
the return line.
TECHNICAL DATA
Factory Pressure Settings Established at 15 L/min.
Maximum Operating Pressure 350 bar
Response Time - Typical 10 ms
Maximum Valve Leakage at 110 SUS (24 cSt) 30 cc/min.
Adjustment - Number of Clockwise Turns to Increase Setting 5
Locknut Hex Size 15 mm
Locknut Torque 9 - 10 Nm
Seal kit - Cartridge Buna: 990-163-007
Seal kit - Cartridge Polyurethane: 990-163-002
Seal kit - Cartridge Viton: 990-163-006
(L)CONTROL
L Standard Screw Adjustment
C Tamper Resistant - Factory Set
K Handknob
(A)ADJUSTMENT RANGE
A 75 - 3000 psi (5 - 210 bar), 1000 psi (70
bar) Standard Setting
W 75 - 4500 psi (5 - 315 bar), 1000 psi (70
bar) Standard Setting
B 75 - 1500 psi (5 - 105 bar), 1000 psi (70
bar) Standard Setting
C 75 - 6000 psi (5 - 420 bar), 1000 psi (70
bar) Standard Setting
N 75 - 800 psi (5 - 55 bar), 400 psi (28
bar) Standard Setting
Q 75 - 400 psi (5 - 28 bar), 200 psi (14
bar) Standard Setting
(N)SEAL MATERIAL
N Buna-N
V Viton
MATERIAL/COATING
Standard Material/Coating
/AP Stainless Steel, Passivated
snhy.com/RSBC
TECHNICAL FEATURES
All 3 port sequence cartridges are physically and functionally interchangeable (i.e. same flow path, same cavity for a given frame size).
Pilot flow continues to increase as the pressure at port 1 (inlet), relative to the pressure at port 3 (drain), rises above the valve setting.
The main stage orifice is protected by a 150 micron stainless steel screen.
Minimum setting is 75 psi (5 bar) for all spring ranges.
Model Code Example: RSBCLANCONFIGURATION OPTIONS
Created on 09/04/2015
c
2015 Sun Hydraulics Corporation See www.sunhydraulics.com for detailed product information 2 of 2
Pressure at port 3 is directly additive to the valve setting at a 1:1 ratio and should not exceed 5000 psi (350 bar).
Not suitable for use in load holding applications due to spool leakage.
Incorporates the Sun floating style construction to minimize the possibility of internal parts binding due to excessive installation torque and/or cavity/cartridge
machining variations.